For Professionals
Criterion 16
Switches, sockets, ventilation and service controls should be at a height usable by all (i.e. between 450 and 1200mm from the floor).
Specification and dimensions which meet the Lifetime Home standards**
This applies to all rooms including the kitchen and bathroom.
Comparison and comments in relation to relevant paragraphs of Approved Document M, 2004 (Part M)
Approved Document M requires that switches and socket outlets and other equipment in habitable rooms are provided at appropriate heights between 450mm and 1200mm from finished floor level.
This is similar to the LTH requirement, but the LTH requirement is more extensive, requiring all service and ventilation controls (e.g. radiator temperature control valves) to be within this height band.